Home » Before and after
  • Control Box Replacement

    Date posted:

    Categories:

    A long term MCI customer asked us for help resolving a problem with the location of control buttons on a number of their machines. The standard machine came with a fixed control box that did not suit the customers operational needs. MCI’s solution was to remove the static control boxes…

    Read more…: Control Box Replacement
  • Replacement Control System

    Date posted:

    Categories:

    MCI was asked by a new customer, that services the oil and gas sector, nuclear power and national fabricators, to replace the control system for a shot blast process. The customer asked not only for us to replace the old panel, but also to redesign it. We were asked to…

    Read more…: Replacement Control System
  • Damaged Touch Screen

    Date posted:

    Categories:

    MCI received a touch screen control panel from one of our regular customers. The touch screen had been damaged by someone using a ballpoint pen on it. MCI’s engineers replaced the damaged parts and tested it before returning it to the customer. One happy customer and the machine was back…

    Read more…: Damaged Touch Screen
  • Vehicle ECU

    Date posted:

    Categories:

    MCI received an ECU for a well known German vehicle. Once our engineers had cleaned the circuitboard up, we were able to diagnose and replace a faulty inductor coil. Another happy customer. If you are having electrical or electronic problems with your vehicles, give MCI a call on 01324 611371…

    Read more…: Vehicle ECU
  • Pastry Machine

    Date posted:

    Categories:

    MCI was called out to look at a customer’s pastry making machine.  Production had halted – no sausage rolls or steak bakes.  Our engineer found the cause of the error and quickly went to work and repaired the machine in good time.  The pastry machine was back producing savoury pastries…

    Read more…: Pastry Machine
  • Machine Control Panel

    Date posted:

    Categories:

    MCI received this machine control panel from a food manufacturer.  Our engineers saw that faulty relays and bases were preventing the machine from running properly.  The job was urgent due to production demand, so we turned the repair around in less than a week for the customer. As you can…

    Read more…: Machine Control Panel
  • Animation showing the before and after of machine drive repaired by MCI Electronics.

    Machine Drive PCB

    Date posted:

    Categories:

    MCI received a machine drive from a hot melt glueing system for MDF boards.  As you can see, the board was badly damaged.  After a good clean up and replacement of damaged parts, the board is back to its old self. If you are having problems with your machine circuitry,…

    Read more…: Machine Drive PCB
  • Animation showing the before and after photos of a railway control board with a blown chip

    Railway Controller

    Date posted:

    Categories:

    MCI received a railway controller from a customer. A chip in the board had clearly blown and the integrated circuit was in need of repair. We believe that an external overload probably caused the fault. MCI replaced the chip and the controller was fixed. If you are having problems with…

    Read more…: Railway Controller
  • Animation showing a CNC display before and after repair.

    Reviving a Failed CNC Display

    Date posted:

    Categories:

    MCI received a CNC display from a customer who manufactures hydraulic rams. The display was a digital read-out for a CNC centre lathe. It had failed due to the age of some of its internal components. MCI replaced the worn components and the power supply to get it working again.…

    Read more…: Reviving a Failed CNC Display
  • Animation showing the before and after photos of a damaged softstart and contactor repair

    Production Line

    Date posted:

    Categories:

    MCI received a call from a new client that was having problems with their production line that had an electrical fault.  After doing some fault finding, our engineer saw that water ingress had caused a motor soft start to fail.  Further investigation also revealed a damaged contactor.  We sourced a…

    Read more…: Production Line